How we calculate

    Methodology and emission factors

    VSME Hub turns the activity data you enter – litres of fuel, kilowatt-hours, kilometres, euros spent – into greenhouse gas emissions. This page sets out the rules it follows and lists every factor it uses, with the published source of each. The same catalogue drives the report editor, the PDF, the brochure and the XBRL export.

    • Published sources only
    • Open licences, cited
    • Each report on its own year
    ACTIVITY4,000 ldiesel, company vansEMISSION FACTOR2.58354kg CO₂e / lDEFRA 2026RESULT · SCOPE 110.33 t CO₂e
    707
    emission factors
    14
    published datasets
    31
    country grids
    2021–26
    reporting years covered

    01Rules

    The rules we follow

    The same rules drive the report editor, the PDF, the brochure and the XBRL export.

    The basics

    • Emissions = activity × emission factor. Results are in tonnes of CO₂ equivalent (t CO₂e). Gases other than CO₂ are converted with their 100-year global warming potential (GWP100) from the IPCC Fifth Assessment Report (AR5) – the set the UK conversion factors and the UNFCCC inventories use.
    • The standard. Scope 1, 2 and 3 follow the GHG Protocol Corporate Standard, as the Voluntary Standard (Commission Delegated Regulation (EU) 2026/1560, Annex I) asks in disclosures B3 and C3.
    • Each report uses the factors of its own year. A 2024 report is priced with the 2024 editions, a 2025 report with the 2025 ones. Where the edition for the reporting year is not published yet, the nearest published year is used – a 2026 report uses DEFRA's 2026 edition, but the AIB 2025 electricity mixes until AIB publishes 2026's (it publishes a year's mixes the following summer). Earlier reports are never re-priced with newer factors, so a year-on-year comparison compares like with like.
    • Nothing is guessed. Where no published factor exists, the row is left out of the total rather than filled in with an estimate. There are no sector benchmarks and no sub-national grid splits.

    Scope 1 – direct emissions

    • Fuels (natural gas, diesel, petrol, LPG, coal): the UK Government GHG Conversion Factors (DEFRA / DESNZ), in kg CO₂e per litre, cubic metre, kilogram or tonne – the total of CO₂, CH₄ and N₂O. Diesel and petrol are the average biofuel blend sold at the pump.
    • Biomass and biofuels (wood logs, chips, pellets, biogas, biodiesel): only their CH₄ and N₂O count in Scope 1. The CO₂ released by burning them is biogenic: it is shown separately, outside the scopes, as the GHG Protocol requires.
    • Refrigerant and SF₆ leaks: the kilograms topped up during the year stand in for the kilograms leaked (the screening method), multiplied by the gas's GWP100. Blends use the mass-weighted GWP of their components. HCFCs such as R-22 are Montreal Protocol gases and stay outside Scope 1.
    • Process emissions: the IPCC default for clinker production (0.52 t CO₂ per tonne of clinker).

    Scope 2 – purchased energy

    • Location-based (what B3 reports): the country's electricity production mix from the AIB European Residual Mixes – direct combustion CO₂, which is what Scope 2 counts. One grid per country. Without a country, the generation-weighted EU-27 average of the same tables (our own arithmetic, labelled as such).
    • Market-based (reported separately): the factor of your contract or supplier where the row gives one (0 for electricity covered by guarantees of origin); otherwise the country's residual mix; where AIB publishes no residual mix (Austria, Switzerland, the Netherlands), the grid average.
    • No lifecycle intensities. Grid factors that include upstream emissions belong in Scope 3 category 3 and are not mixed into Scope 2.
    • District heat and steam: the heat supplier's own factor when you enter it, otherwise DEFRA's district heat and steam factor. District cooling is counted only with the supplier's factor, as there is no published default. Heat and cooling count the same in both methods.
    • The same kilowatt-hours may be entered once per method; the two methods are never added together.

    Scope 3 – the value chain

    • Activity-based factors (materials, freight in tonne-kilometres, business travel, commuting, homeworking, waste, wastewater, hotel nights): DEFRA / DESNZ, each with the row it was read from. Flights are without the radiative forcing uplift. Waste sent to recycling or energy recovery carries only its transport, as DEFRA counts it.
    • Electricity-based activities (leased assets, processing and use of sold products) use the location-based grid factor of the report's country – the Scope 2 rows of the table below.
    • Spend-based factors (kg CO₂e per euro) are the Defra / University of Leeds multipliers by product group (2023, excluding VAT), converted from pounds at the 2023 average rate of 0.8698 £/€. We do not use EXIOBASE: its licence does not allow publishing factors derived from it.
    • Supplier-specific (category 1): when a supplier answers your data request, its own intensity – Scope 1, location-based Scope 2 and upstream Scope 3 over its turnover – times what you bought from it.
    • Value-chain overview (Suppliers → Overview): each supplier's purchase is priced with its own intensity when it answered, otherwise estimated from the spend with the multiplier of its NACE division (or the general goods / services row). Data quality levels, a simplification of the GHG Protocol Scope 3 Standard's data quality criteria: A – supplier data with Scope 1, Scope 2 and turnover for the year itself and no warnings; B – supplier data with a gap (warnings, an earlier year – never a later one, a missing scope, or Scope 3 only as a total); C – estimate with the NACE division's multiplier; D – estimate with the general multiplier. Coverage is the share of the spend with A or B data. The estimates are never a sector comparison and do not enter the report on their own.
    • Supplier screening (Suppliers → Risk): findings read only from each supplier's own VSME answer for the year – no outside data and no rating. Critical: a work-related fatality (B9), a corruption conviction or fine (B11), a confirmed human rights incident (C7). Gap: no practice or policy on the environment, workforce, human rights or anti-corruption (B2), Scope 1 or 2 missing (B3), pay below the minimum wage (B10), no code of conduct covering child labour, forced labour and trafficking, or no complaints mechanism (C6). Watch, never counted in the score: accidents (B9), sites in or near biodiversity-sensitive areas (B5), revenue from the C8 sectors. Only requested modules count, and an unanswered question is never read as "no". The score is the share of the critical and gap checks that could be read without a finding; it is shown only when at least three of them could be read. A country's status comes from official EU lists only, each with its source and the date it was last checked: EU/EEA, a Commission adequacy decision under GDPR Article 45 (for Canada and the United States only part of the organisations), another third country, or the EU list of high-risk third countries for money laundering (Delegated Regulation 2016/1675 as amended).

    Energy (B3)

    Fuel consumption in megawatt-hours is calculated from the same Scope 1 fuel rows with each fuel's net calorific value (DEFRA "Fuel properties"); biomass and biofuel rows count as renewable. The renewable share of purchased electricity is calculated only when every electricity row states it; otherwise the figures you typed in stay.

    Company groups (consolidated report)

    • Each company is calculated on its own first. Every subsidiary's report for the same year is calculated with its own country – its electricity on its own country's grid – and only then added to the parent's figures. A subsidiary with no report for that year is left out, and the preview names it.
    • Every company counts in full. Absolute figures (energy, emissions, waste, people, money) are added up at 100%, whatever the ownership share: the share is recorded, not applied.
    • Ratios are recalculated, not averaged. Shares and intensities are computed again from the summed figures; rates entered per employee are weighted by headcount. A yes/no answer is the group's "yes" for incidents if any company reports one, and for policies only if every company has one.
    • No intra-group eliminations. Sales and purchases between group companies are not netted out. If the consolidated financial statements show a different turnover or balance sheet total, enter those after consolidating. When one group company buys from another and counts that purchase in its Scope 3, the seller's Scope 1 and 2 already contain the same emissions – check such rows by hand.

    What the figures are not

    The results are an estimate made with published average factors. They are not verified or assured by a third party, and they are not a product carbon footprint. Where you have better data – your electricity contract's factor, your heat supplier's factor, a supplier's own emissions – enter it in the row: it takes precedence over the catalogue.

    02Sources

    Sources and licences

    Every factor comes from one of these published datasets. Each row of the table names the exact line it was read from.

    • DEFRA / DESNZ

      UK Government GHG Conversion Factors

      359factors

      Editions (each opens its source)

      Licence: Open Government Licence v3.0 - attribution

    • AIB

      European Residual Mixes

      303factors

      Editions (each opens its source)

      Licence: AIB published results - free use with a reference to AIB (the underlying per-technology factors are not used)

    • Defra / University of Leeds

      UK carbon footprint – spend-based multipliers

      37factors

      Editions (each opens its source)

      Licence: Open Government Licence v3.0 - attribution

    • IPCC

      AR5 GWP100 · 2019 Refinement to the 2006 Guidelines

      8factors

      Editions (each opens its source)

      Licence: IPCC published values - cited with the report

    03Factors

    Every factor

    The values the calculations use, as stored. Filter by type, country or year; subscribers can also download the whole table as CSV.

    707 of 707 factors

    04Changes

    What changed

    Each change to the catalogue, newest first. Calculated figures are always worked out again from the activity rows with the factors of the report's own year: a corrected factor reaches every report of that year, while a newer edition never reaches an earlier year.

    1. Earlier years: the DEFRA 2021, 2022 and 2023 editions (Scope 1 fuels and bioenergy, net calorific values, district heat, activity-based Scope 3; 2021 has no homeworking factor, so 2022's is used) and the AIB 2021 and 2022 production and residual mixes, with the EU-27 average calculated the same way. Reports for 2021-2023 were priced with the nearest edition (2024 DEFRA, 2023 AIB) until now; they now use their own year's.

      DEFRA / DESNZ 2021DEFRA / DESNZ 2022DEFRA / DESNZ 2023AIB 2021AIB 2022

    2. DEFRA 2026 edition added (flat file revised July 2026) for 2026 reports: Scope 1 fuels and bioenergy, net calorific values, district heat and activity-based Scope 3. Natural gas 2.06672 → 2.02633 kg/m³, diesel 2.57082 → 2.58354 kg/l, road freight 0.10163 → 0.10356 kg/tkm, national rail 0.03546 → 0.03092 kg/pkm. Reports for 2025 and earlier are unchanged. Electricity stays on the AIB 2025 mixes until AIB publishes 2026 (expected summer 2027).

      DEFRA / DESNZ 2026

    3. B3 fuel consumption in MWh is now calculated from the Scope 1 fuel rows, with the net calorific values of DEFRA's Fuel properties (2024 and 2025 editions).

      DEFRA / DESNZ 2024DEFRA / DESNZ 2025

    4. Spend-based Scope 3 factors switched to the Defra / University of Leeds multipliers by product group (2023, excluding VAT); EXIOBASE and unsourced averages removed.

      Defra / University of Leeds 2023

    5. Scope 1 and activity-based Scope 3 factors re-read from the exact DEFRA 2024 and 2025 rows; biomass and biofuels now carry only CH₄ and N₂O, with their CO₂ shown apart as biogenic; IPCC default for clinker; SF₆ added.

      DEFRA / DESNZ 2024DEFRA / DESNZ 2025IPCC 2019IPCC 2013

    6. Scope 2 electricity factors from the AIB European Residual Mixes 2023–2025: the production mix for location-based, the residual mix for market-based, direct CO₂ only. Illustrative regional splits removed.

      AIB 2023AIB 2024AIB 2025

    7. District heat and steam (DEFRA 2024 and 2025) and refrigerant leaks (IPCC AR5 GWP100) added.

      DEFRA / DESNZ 2024DEFRA / DESNZ 2025IPCC 2013