Transparent emission factors – where our numbers come from
Every tonne of CO₂e in a VSME report is activity data times a published factor. Which factors VSME Hub uses, why each report keeps its own year's figures, and how to trace a result back to its source.
Sooner or later someone reads your VSME report and asks: "where does this 12.4 tonnes come from?" It might be a bank, an auditor or a customer's sustainability team. A good answer has two parts: the data you entered, and the factor it was multiplied by. The first part is yours. The second is ours, so we publish it.
Emissions are activity times a factor
Nobody measures CO₂ at a chimney for a VSME report. You enter what you already have on your bills, such as litres of diesel, cubic metres of gas and kilowatt-hours of electricity. Each line is multiplied by an emission factor, the published average emissions per unit. The result is in tonnes of CO₂ equivalent, with methane and nitrous oxide converted using their 100-year global warming potential (GWP100).
The method follows the GHG Protocol, as disclosures B3 and C3 of the Voluntary Standard ask. The factors are the part a reader cannot check without seeing them. Our methodology page now lists every one of them, each with the dataset and row it was read from.
Where the factors come from
- Fuels (Scope 1): the UK Government GHG Conversion Factors (DESNZ / DEFRA), 2021 to 2026 editions. Diesel and petrol are the average biofuel blend sold at the pump.
- Electricity (Scope 2): the AIB European Residual Mixes. The country's production mix is used for the location-based figure, its residual mix for the market-based one. Both count direct CO₂ only, as Scope 2 does. We use one grid per country.
- Refrigerants: the GWP100 values of the IPCC Fifth Assessment Report (AR5).
- Scope 3 by spend: the Defra / University of Leeds multipliers by product group (2023, excluding VAT), converted from pounds to euros.
All of these are published under terms that allow reuse with attribution. We deliberately left out EXIOBASE, whose licence does not allow publishing factors derived from it. We also left out lifecycle grid intensities, whose upstream part belongs in Scope 3, not Scope 2.
A worked example with the 2025 factors
A small company with vans, a gas boiler and an office in Hungary reports for 2025:
| Activity | Quantity | Factor (2025) | Emissions |
|---|---|---|---|
| Diesel, vans | 4,000 l | 2.57082 kg CO₂e/l | 10.28 t |
| Natural gas, heating | 3,000 m³ | 2.06672 kg CO₂e/m³ | 6.20 t |
| Electricity, Hungary (location-based) | 48,000 kWh | 0.1409 kg CO₂e/kWh | 6.76 t |
Scope 1 is 16.48 t and location-based Scope 2 is 6.76 t. Every factor in the table is a row you can find on the methodology page by searching for the fuel or the country.
The market-based figure is a separate number. With no green contract, the same 48,000 kWh are priced at Hungary's 2025 residual mix, 0.4535 kg CO₂e/kWh, which gives 21.77 t. With electricity covered by guarantees of origin it is 0 t. The two methods describe the same kilowatt-hours, so they are never added together. B3 reports the location-based figure.
Biogenic CO₂ is kept apart. If the company also burned 10 tonnes of wood logs, only their methane and nitrous oxide count in Scope 1: 0.47 t. The 14.36 t of CO₂ from the wood itself is biogenic. It is shown next to the scopes, not inside them, as the GHG Protocol requires.
Each report keeps its own year
Grid electricity changes from year to year. Hungary's production mix was 0.1772 kg CO₂e/kWh in the 2024 edition and 0.1409 in the 2025 one. The same 48,000 kWh is 8.51 t in a 2024 report and 6.76 t in a 2025 report.
That is why every report is calculated with the factors of its own reporting year, and an older report is never re-priced when a new edition comes out. A year-on-year comparison then shows what changed in your company, alongside what changed in the grid, without one hiding the other. Where the edition for a year is not published yet, the nearest earlier one is used until it is.
When we add or correct a factor, the change goes into a dated change log on the methodology page, and a test fails until it is there.
What the numbers are not
They are an estimate made with published averages. Nobody verifies them for you, and they are not a product carbon footprint. Where you have better data, such as your electricity contract's factor, your heat supplier's figure or a supplier's own emissions, enter it in the row. It takes precedence over the catalogue. Where no published factor exists, the row is left out of the total rather than filled in with a guess.
Check it yourself
Open the methodology page, search for a fuel or a country, and compare the factor with the one in your report. Anyone can browse and filter the table. Subscribers can also download it as a CSV.
Sources
- 1.UK Government GHG Conversion Factors 2025 (DESNZ / DEFRA)
- 2.UK Government GHG Conversion Factors 2026 (DESNZ / DEFRA)
- 3.AIB – European Residual Mixes 2025
- 4.IPCC – Fifth Assessment Report (AR5), Working Group I
- 5.Defra – UK's carbon footprint (spend-based multipliers, University of Leeds)
- 6.GHG Protocol – Scope 2 Guidance
- 7.Commission Delegated Regulation (EU) 2026/1560 – the Voluntary Standard (EUR-Lex)
This post is general information, not legal advice. Rules and official materials change - always check the current text at the official source.